Nsls Ii Injection Straight Diagnostics
Download and Read Nsls Ii Injection Straight Diagnostics full books in PDF, ePUB, and Kindle. Read online free Nsls Ii Injection Straight Diagnostics ebook anywhere anytime directly on your device. We cannot guarantee that every ebooks is available!
NSLS-II INJECTION STRAIGHT DIAGNOSTICS.
Author | : |
Publisher | : |
Total Pages | : |
Release | : 2011 |
Genre | : |
ISBN | : |
Download NSLS-II INJECTION STRAIGHT DIAGNOSTICS. Book in PDF, Epub and Kindle
The ultra-bright light source being developed by the NSLS-II project will utilize top-up injection and fine tuning of the injection process is mandatory. In this paper we present the diagnostics installed in the injection straight. Its use for commissioning and tuning of the injection cycle is also described. The NSLS-II storage ring will utilize a 9.3 meter long injection straight section shown in Fig. 1. Injection will be preformed with two septa (one pulsed, one DC) and four kickers. The stored beam will be shifted towards the pulsed septum up to IS mm and the nominal distance between centers of the injected and the bumped beam is 9.5mm. The NSLS-II beam position monitors will have turn-by-turn and first-turn capabilities and will be used for the commissioning and tuning the injection process. However, there are three additional BPMs and two beam intercepting OTR screens (flags) installed in the injection straight.