Performance of the Diagnostics for NSLS-II Linac Commissioning

Performance of the Diagnostics for NSLS-II Linac Commissioning
Author:
Publisher:
Total Pages:
Release: 2011
Genre:
ISBN:


Download Performance of the Diagnostics for NSLS-II Linac Commissioning Book in PDF, Epub and Kindle

The National Synchrotron Light Source II (NSLS-II) is a state of the art 3-GeV third generation light source currently under construction at Brookhaven National Laboratory. The NSLS-II injection system consists of a 200 MeV linac, a 3-GeV booster synchrotron and associated transfer lines. The transfer lines not only provide a means to deliver the beam from one machine to another, they also provide a suite of diagnostics and utilities to measure the properties of the beam to be delivered. In this paper we discuss the suite of diagnostics that will be used to commission the NSLS-II linac and measure the beam properties. The linac to booster transfer line can measure the linac emittance with a three screens measurement or a quadrupole scan. Energy and energy spread are measured in a dispersive section. Total charge and charge uniformity are measured with wall current monitors in the linac and transformers in the transfer line. We show that the performance of the diagnostics in the transfer line will be sufficient to ensure the linac meets its specifications and provides a means of trouble shooting and studying the linac in future operation.


Performance of the Diagnostics for NSLS-II Linac Commissioning
Language: en
Pages:
Authors:
Categories:
Type: BOOK - Published: 2011 - Publisher:

GET EBOOK

The National Synchrotron Light Source II (NSLS-II) is a state of the art 3-GeV third generation light source currently under construction at Brookhaven National
Beam Transport and Diagnostics for the NSLS-II Injection System
Language: en
Pages:
Authors:
Categories:
Type: BOOK - Published: 2009 - Publisher:

GET EBOOK

The NSLS-II is a state of the art 3 GeV synchrotron light source being developed at BNL. The injection system will consist of a 200 MeV linac, 3 GeV booster syn
PHYSICS RESULTS OF THE NSLS-II LINAC FRONT END TEST STAND.
Language: en
Pages:
Authors:
Categories:
Type: BOOK - Published: 2012 - Publisher:

GET EBOOK

The Linac Front End Test Stand (LFETS) was installed at the Source Development Laboratory (SDL) in the fall of 2011 in order to test the Linac Front End. The go
NSLS-II Transport Line Progress
Language: en
Pages:
Authors:
Categories:
Type: BOOK - Published: 2012 - Publisher:

GET EBOOK

The National Synchrotron Light Source II (NSLS-II) is a state-of-the-art 3-GeV third generation light source currently under construction at Brookhaven National
NSLS-II Injector Commissioning and Initial Operation*
Language: en
Pages:
Authors:
Categories:
Type: BOOK - Published: 2015 - Publisher:

GET EBOOK

The injector for the National Synchrotron Light Source II (NSLS-II) storage ring consists of a 3 GeV booster synchrotron and a 200 MeV S-band linac. The linac w